TENS/EMS

FDES108

TENS & EMS DualPad

FDES108

For program of TENS mode

To be used for temporary relief of pain associated with

sore and aching muscles due to strain from exercise or

normal household work activities.


For program of EMS mode

To be used to stimulate healthy muscles in order to improve

and facilitate muscle performance.



Suggested retail price:$

Features
Intended use
For program of TENS mode
To be used for temporary relief of pain associated with sore and aching muscles due to strain
from exercise or normal household work activities.


For program of EMS mode
To be used to stimulate healthy muscles in order to improve and facilitate muscle performance.

What is Electrical Stimulator and what can it do?
Digital TENS/EMS belongs to the group of electrical stimulation systems. It has two basic functions,
which can be used in combination.
1. Electrical stimulation to nerve tracts (TENS)
2. Electrical stimulation to muscle tissue (EMS)
It has various versatile functions in order to increase general well-being, alleviate pain, maintain physical
fitness,relaxation, and revitalize muscles and combat fatigue. You can either select these functions from
preset programs or determine them yourself according to your requirements.

The operation principle of electrical stimulation equipment is based on simulating the body's own pulses
which are transmitted transcutaneous to nerve or muscle fibers by means of electrodes. The electrodes can
thereby be attached to many parts of the body, whereby the electrical stimuli are safe and practically
painless. You will merely feel a gentle prickling or vibrating sensation in some applications. The electrical
pulses transmitted to the tissue affect the transmission of stimulation in nerve conductions as well as
Neuron and muscle tissue in the field of application.

Electrical stimulation does not replace regular exercising of the muscle, but is able to reasonably supplement
the effect thereof

TENS, Transcutaneous Electrical Nerve Stimulation, means electrical stimulation of nerves through the skin. It is a
non-medical method of treating pain from certain causes. TENS uses tiny electrical impulses sent through the skin
to nerves to modify your pain perception. TENS does not cure any physiological problem; it only helps control the
pain. TENS does not work for everyone; however, in most patients it is effective in reducing or eliminating the pain,
allowing for a return to normal activity.



TENS is clinically tested and approved with the following applications:



EMS, Electrical Muscle Stimulation, is a widespread and generally recognized method and has been
used for years in sports and rehabilitation medicine. In the sports and fitness field, one of the uses of EMS
is as a supplement to conventional muscle training, in order to increase the efficiency of muscle groups
and adapt physical proportions to the desired aesthetic results. EMS application goes in two directions. On
one hand, a targeted strengthening of musculature can be produced (Activating application) and on the
other hand a relaxing, resting effect can also be achieved (relaxing application)



Active application includes the following:




Relaxing application includes the following:







Basic Information
hannel Dual, isolated between output channels
Operating conditions 5°C to 40°C (41°F to 104°F) with a relative humidity of 30%-85%,atmospheric pressure from 70 to 106 kPa
Storage conditions -10°C to 55°C (14°F to 122°F) with a relative humidity of 20%-93%,atmospheric pressure from 70 to 106 kPa
Power supply DC 4.5V , 1.5x3(AAA) battery
DC capacity, Maximum Amplitude and Load Impedance Equipment output DC capacity: 0,
Maximum output one-way peak value voltage 40V±20%,
Load Impedance: 500 Ohms
Power save time I Wait<10mA
Power Off Current I Off<150uA
Dimensions 110×59.5×30(mm)(L×W×H)
Weight 45g(Without battery)
Tolerance There may be a ±10% tolerance of all setting (frequency, pulse width) and ±20% tolerance of output of intensity.
Electrode Detection Function The amplitude level will be reset to 0mA when the amplitude level is 10mA or greater and an open circuit at either channel is detected.